top of page
Screen Shot 2019-07-10 at 12.28.06 PM.pn

RAISING THE FLANGE TO FINISHED FLOOR LEVEL

Screen Shot 2019-07-10 at 2.43.12 PM.png

STEP 1

Measure from the sub-floor to the finished floor. The FlexOn Flange corrects flange elevation from 3/8" to 1 1/8".

feature-auWl6.png

STEP 2

Attach spacers.

Screen Shot 2019-07-10 at 2.44.07 PM.png

STEP 3

Wet the outer side of the sleeve. Fold flexible sleeve inwards to insert to 4" drain pipe.

Screen Shot 2019-07-10 at 2.44.15 PM.png

STEP 4

Verify that flange is at the correct height to ensure a perfect seal with the toilet horn, using the FlexOn
Gauge included.

How to insert

into the pipe

FLANGE REPLACEMENT

The FlexOn Flange can be used on top of any flange, considering that:

​

a)  The existing flange does not interfere with the inner diameter of the drain pipe, 4" is required

b)  The existing flange is even or below the finished floor level.

 

Please note: 

Spigot-Flange.png

An existing spigot flange must be removed prior to installation.

Hub-Flange.jpg

An existing hub flange does not need to be removed if it is even or below the finished floor.

bottom of page